Overview
The LSC APS is a 3RU, 19 inch rackmount power distribution unit that controls large inrush currents, earth leakage and overloads when powering LED screens, audio amplifiers and moving lights. Each circuit can be soft started in sequence with a programmed delay, relays switch at the zero crossing of the mains, and several APS units can be cascaded so each one waits for the last to finish starting up.
Every channel has its own RCBO with a 30 mA trip, and the unit adds dropped neutral protection with near instant load disconnect and programmable over and under voltage cut-off on each phase. Control is from the 3.2 inch colour touchscreen, DMX/RDM or GPI contact closure, with remote monitoring over RDM or HOUSTON X. Choose 12 x 10A, 12 x 16A, 12 x 6A single phase or 6 x 25A, with GPO, powerCON, powerCON TRUE1, Wieland, Socapex or hardwired terminal outputs, to suit touring racks, hire stock, theatres and venues.
Highlights
- 12 x 10A, 12 x 16A, 12 x 6A single phase or 6 x 25A
- GPO, powerCON, powerCON TRUE1, Wieland, Socapex or hardwired outputs
- Sequential soft start per circuit, cascading between units
- RCBO with 30 mA trip on every channel
- Dropped neutral protection and over and under voltage cut-off per phase
- 3.2 inch colour touchscreen, DMX/RDM and GPI control
- Remote monitoring via RDM or LSC HOUSTON X
- Australian designed and made, five year warranty
Specifications
| Channels | 12 x 10A, 12 x 16A, 12 x 6A (single phase SP10) or 6 x 25A |
| Outputs (rear) | Australian GPO, powerCON, powerCON TRUE1, 2 x 16-pin Wieland, 2 x 19-pin Socapex, Socapex plus 3 x powerCON TRUE1 (parallel with circuits 1 to 3) or screw terminals, depending on model |
| Protection | RCBO per channel, 30 mA trip; dropped neutral protection; programmable min and max voltage cut-off per phase |
| Start-up | Programmable sequential start per channel, cascading between units, zero cross relay switching |
| Control | 3.2 inch colour LCD touchscreen, DMX512/DMX512-A with RDM on 5-pin XLR, GPI contact closure |
| Monitoring | 3-phase voltage and current on the display; remote via RDM and HOUSTON X |
| Power | 100 to 240 V, 3-phase star, 50 to 60 Hz (single phase operation possible, 63A max) |
| Input | 1.2 m H07 5 core tail: 32A 5-pin plug (12 x 10A), 63A CeeForm plug (12 x 16A), 40A 5-pin plug (6 x 25A); terminals on hardwired T models; single phase 10A tail and plug with 10A thermal input breaker on SP10 |
| Dimensions | 483 x 300 x 132 mm (W x D x H), 3RU |
| Weight | 11 kg |
| Warranty | Five years, designed and made in Australia |
Forefront Tip
Set a short start-up delay per circuit for amp racks, LED walls and moving light bars so they come up one at a time instead of tripping the supply, and cascade the units so each rack waits for the last. In venues, use the DMX auto on/off so the rig powers down after the desk is switched off.